Hemodynamic Monitoring and Correlation Between Electrical Cardiometry and Esophageal Doppler in Patients Undergoing Major Abdominal Surgery

  • STATUS
    Recruiting
  • participants needed
    35
  • sponsor
    Cairo University
Updated on 16 February 2024

Summary

The aim of this study is to correlate hemodynamic monitoring between noninvasive Electrical Cardiometry and minimally invasive Esophageal Doppler in patients undergoing major abdominal surgery

Description

Cardiac output (CO) and Stroke Volume (SV) can be used as markers for global cardiovascular functions and can assess fluid responsiveness to ensure adequate tissue perfusion which is one of the essential concerns of anesthestists and intensivists The gold standard is the thermodilution procedure by pulmonary artery catheter (PAC), yet, cannot be considered as a routine owing to potential difficulty and virtual complications The development of safe, simple, minimally invasive or non-invasive techniques which estimate CO, SV and systemic vascular resistance (SVR) without invasive intravascular catheterization or dye injection is important for clinical decision-making and research in anesthesia and critical care medicine Echocardiography in comparison with other Doppler modalities is a potent diagnostic mean that has the superiority above the traditional PAC for both diagnostic precision and rapidity However, the use of echocardiography needs good training and relatively expensive. Another ultrasound based device is Esophageal Doppler(ED) which looks more suitable for prolonged hemodynamic monitoring. This technique is minimally invasive which calculates the blood flow velocity in descending aorta and can determine SV and CO with sound trustworthiness. Such technique needs less training than standard echocardiography or PAC Thoracic Electric Bioimpedance (TEB) is a noninvasive monitoring which correlates differences in thoracic electrical conductivity to thoracic aortic blood volume and flow. It is a simple method for detection of SV, CO, contractility, SVR, and thoracic fluid content (TFC) for continuous monitoring. The results of previous studies comparing impedance cardiography with thermo dilution and other methods like transoesophageal echocardiography (TEE) have been largely inconclusive which may referred to higher thorax fluid content and consequently higher conductivity after surgical procedure To overcome these problems, upgraded computer equipment and advanced algorithms are used in the newer model; electrical cardiometry (EC), that interprets the maximum changes in TEB and can calculate CO accurately in adults and neonates Although other study compared between two devices in patients undergoing major abdominal and pelvic surgeries , but the sample size was small rather than our study , also it included laparoscopic surgeries which affect hemodynamics (blood pressure , heart rate and other cardiac parameters ) in such points . In addition investigators used the old version of thoracic bio-impedance (NICOM) which is different from our device as we will us (ICON) , Like another study comparing between two devices used also the old version of thoracic bio-impedance and didn't specify the type of surgery at which the study was done . There are also other studies comparing the two devices one of them in paediatrics undergoing kasai operation and the second in patients during liver transplantation , these two studies contain two types of patients not included in the present study .

Details
Condition Electrical Cardiometry VS Esophageal Doppler
Age 20years - 60years
Treatment Esophageal doppler
Clinical Study IdentifierNCT04255550
SponsorCairo University
Last Modified on16 February 2024

Eligibility

Yes No Not Sure

Inclusion Criteria

Geriatric patients
American Society of Anesthesiologists (ASA) physical status II or III
Patients listed for elective major abdominal surgery such as (e.g. cancer stomach, colon, bladder, or pancreas)

Exclusion Criteria

Age <50 years
Patients with hemodynamic instability and on inotropes which means ( perfusion failure, represented by clinical features of circulatory shock and advanced heart failure , It may also be defined as 1 or more out-of-range vital sign measurements, such as low blood pressure)
Coagulopathies (platelet < 100109/L, PT > 16 s and INR > 1.2)
History of esophageal pathology
Patient needed massive blood transfusion intraoperatively which means replacement of >1 blood volume in 24 hours or >50% of blood volume in 4 hours (adult blood volume is approximately 70 mL/kg)
Clear my responses

How to participate?

Step 1 Connect with a study center
Message sent successfully.
We have submitted the information you provided to the research team at the location you chose. For your records, we have sent a copy of the message to your email address.
If you would like to be informed of other studies that may be of interest to you, you may sign up for Patient Notification Service.
Sign up

Send a message

Enter your contact details to connect with study team


Email

View email

Phone

Phone country flag

View phone
Investigator Avatar

Primary Contact

First name*
Last name*
Email*
Phone number*
Other language

Additional screening procedures may be conducted by the study team before you can be confirmed eligible to participate.

Learn more

If you are confirmed eligible after full screening, you will be required to understand and sign the informed consent if you decide to enroll in the study. Once enrolled you may be asked to make scheduled visits over a period of time.

Learn more

Complete your scheduled study participation activities and then you are done. You may receive summary of study results if provided by the sponsor.

Learn more

Similar trials to consider

Loading...

Not finding what you're looking for?

Every year hundreds of thousands of volunteers step forward to participate in research. Sign up as a volunteer and receive email notifications when clinical trials are posted in the medical category of interest to you.

Sign up as volunteer
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.