Comparison of surgical technique for the execution of bone resections in total knee arthroplasty.
Used technique are: a non-invasive extramedullary technique (EM technique) based on the use of inertial sensors for cutting guides positioning and conventional technique (IM technique), based on the use on intramedullary stem.
Our hypothesis is that the EM technique based on the use of inertial sensors leads to a reduction in the number of outliers equal to or greater than 20% compared to the outliers obtained with the conventional technique.
Description
Comparison of surgical technique for the execution of bone resections in total knee arthroplasty.
Used technique are: a non-invasive extramedullary technique (EM technique) based on the use of inertial sensors for cutting guides positioning and conventional technique (IM technique), based on the use on intramedullary stem. A study was carried out at the Rizzoli Orthopedic Institute in 2016 to compare non-invasive extramedullary technique (EM technique) and conventional technique (IM technique). Starting from the results obtained in the previous study, the objective of this study is to deepen the investigations to evaluate the effectiveness of the EM technique compared to the conventional IM technique.
The patients involved in the study will be divided into two groups based on the alignment technique used (EM technique and IM technique).
The results obtained will be measured on postoperative panoramic radiographs at discharge, assessing the overall alignment of the limb and the individual femoral and tibial components in terms of accuracy and repeatability according to a defined measurement protocol.
Primary endpoint:
- reduction in the number of cases in which the alignment error on the coronal plane is greater than 3of error (outlier). Our hypothesis is that the EM technique based on the use of inertial sensors leads to a reduction in the number of outliers equal to or greater than 20% compared to the outliers obtained with the conventional technique.
Secondary endpoints:
- the reduction of the variation in hemoglobin levels during hospitalization. Our hypothesis is that the EM technique leads to a reduction in the maximum variation of hemoglobin levels during the hospitalization period compared to the IM technique equal to or greater than 1g / dl
- reduction of alignment errors of the femoral and tibial resections obtained with the EM technique and with the IM technique on the sagittal plane. In particular, the experimental hypothesis is that in the EM technique group, values of alignment of the implant with respect to the femoral and tibial mechanical axis on the sagittal plane are not significantly lower than those obtained with the standard technique but with a reduction in the standard deviation in the EM group compared to the IM group.
- reduction of the period of hospital stay in the EM group compared to the group operated with the standard technique.
- inter-operator variability in the EM group Randomized controlled multicenter prospective study. The evaluation of the results obtained will be blinded by an examiner with adequate clinical skills and who does not take part in the operational phases of the study.
Duration: 36 months The patients will be divided into 2 groups, based on the alignment technique used Total number of patients involved: 180 (90 Group A Patients: EM Technique), (90 Group B Patients: IM Technique) Total number of centers involved: 3 Patients per Center: 30 Group A Patients, 30 Group B Patients Patients will be randomized. The randomization list will be generated using the website www.randomization.com. This list will be kept at the Operative Unit Orthopedic and Traumatological Clinic 2nd and will not be visible to the investigators involved The evaluation of the results obtained will be carried out blindly by an examiner with adequate clinical skills to carry out the evaluation and who does not take part in the operational phases of the study.
For both groups of patients, the results obtained will be measured on postoperative panoramic radiographs performed at discharge, assessing in terms of accuracy and repeatability.
Finally, within Group A, the inter-operator variability of the measurement of the final femoral and tibial alignment obtained using the Blant & Altman analysis method will be assessed
The study involves the collection of data in three different phases:
Preoperative phase:
- Panoramic radiography under weight-bearing of the lower limbs in A-P and radiography of the knee in lateral projection
- laboratory value of hemoglobin
Intraoperative phase:
- Time of application of the ischemic snare;
- Surgery time;
- Final femoral and tibial alignment. In Group A the acquisition is repeated 2 times by two operators.
- Number of repetitions of distal femoral and tibial resections;
- Possible administration of blood products;
- Blood loss;
Post-operative phase
- Panoramic X-ray under weight-bearing of the lower limbs in A-P and knee radiography in lateral projection (at discharge)
- laboratory value of the patient's hemoglobin on each day until the date of discharge
- possible administration of blood products
- hospitalization times All data will be collected in a data collection form associated with the patient.
The preoperative and postoperative radiographs (made anonymous) and the data collection form will be sent to the coordinating center which will carry out the measurements.
From the literature it emerges that in order to detect a difference between the two techniques of 20% on the number of outliers (alignment of the components >3on the coronal plane) with an alpha type error (level of significance) equal to 0.05 and a power of at least 0.8, the minimum number of samples needed per group is 82 cases. Considering a 10% drop out, a sample of 90 cases per group is expected (divided into 3 centers for a total of 30 cases per group in each center)
Details
Condition | Osteoarthritis of knee, Osteoarthritis, Osteoarthritis |
---|---|
Age | 40years - 80years |
Treatment | Total knee replacement |
Clinical Study Identifier | NCT04242303 |
Sponsor | Istituto Ortopedico Rizzoli |
Last Modified on | 16 February 2024 |
How to participate?
Additional screening procedures may be conducted by the study team before you can be confirmed eligible to participate.
Learn moreIf you are confirmed eligible after full screening, you will be required to understand and sign the informed consent if you decide to enroll in the study. Once enrolled you may be asked to make scheduled visits over a period of time.
Learn moreComplete your scheduled study participation activities and then you are done. You may receive summary of study results if provided by the sponsor.
Learn moreSimilar trials to consider
Browse trials for
Not finding what you're looking for?
Sign up as a volunteer to stay informed
Every year hundreds of thousands of volunteers step forward to participate in research. Sign up as a volunteer and receive email notifications when clinical trials are posted in the medical category of interest to you.
Sign up as volunteerStudy Definition
WikipediaAdd a private note
- Select a piece of text.
- Add notes visible only to you.
- Send it to people through a passcode protected link.